ZW32-12(G)T Outdoor High Voltage AC Vacuum Circuit Breaker
Product Overvie
Three-phase AC 50Hz outdoor high-voltage switchgear, suitable for 10kV rural and urban power systems, used for breaking and closing load current, overload current, short-circuit current and other similar places.
Implementation standards
GBT1984 《High-voltage AC circuit breaker》
GBT11022 《Common technical requirements for high-voltage switchgear and control equipment standards 》DLT 402 《High-voltage AC circuit breaker》
Product naming rules

Product Parameters
| No. | Parameter name | Unit | Data | |||
| 1 | Rated voltage | KV | 12 | |||
| 2 | Rated current | A | 630 1250 | |||
| 3 | Rated frequency | Hz | 50 | |||
| 4 | Rated insulation level | 1min power frequency withstand voltage | Dry test | KV | Between phases, to ground 42/break 48 | |
| Wet test | 34 | |||||
| Lightning impulse withstand voltage (peak value) | Between phases, to ground 75/break 85 | |||||
| 5 | Rated short-circuit breaking current | KA | 20 | 25 | ||
| 6 | Rated short-circuit closing current (peak value) | KA | 50 | 63 | ||
| 7 | Rated peak withstand current | KA | 50 | 63 | ||
| 8 | 4s thermal stability current | KA | 20 | 25 | ||
| 9 | Rated operating sequence | 0-0.3s-CO-180s-CO | ||||
| 10 | Closing time | ms | ≤50 | |||
| 11 | Opening time | ≤45 | ||||
| 12 | Rated short-circuit breaking current breaking times | time | 30 | |||
| 13 | Mechanical life | 10000 | ||||
| 14 | 1min power frequency withstand voltage for control circuit and auxiliary circuit | V | 2000 | |||
| 15 | Rated operating voltage and auxiliary voltage | AC/DC220,DC110/48/24 | ||||
| 16 | Rated current of overcurrent trip coil | A | 5 | |||
| 17 | Allowable wear thickness of dynamic and static contacts of extinguishing chamber | mm | 3 | |||
Environmental conditions for use
◆ Ambient air temperature: maximum temperature +45℃, minimum temperature -40℃, maximum daily temperature difference 25K;
◆relative humidity: daily average value not more than 95%, monthly average value not more than 90%;
◆Altitude: not more than 2000 meters:
◆parent wind speed: not more than 35m/'s (equivalent to wind pressure 700 Pa);
◆Pollution level: W level;
◆ Ice thickness: 10 mm;
◆Earthquake resistance: horizontal acceleration 0.3gm/s, vertical acceleration 0.2g m/s"; 4.8 No fire, explosion, chemical corrosion and frequent severe vibration.
If it exceeds the requirements of normal use conditions, it needs to be negotiated and customized with the manufacturer.
Product technical features
◆The product mainly consists of three-phase poles, spring operating mechanism, transmission system, conductive circuit, control unit and shell (ordinary carbon steel plastic or stainless steel); the overall structure is a three-phase pillar type, with a miniaturized design, a fully enclosed structure, and good sealing performance, which is particularly suitable for use in cold and humid areas;
◆It adopts an efficient and reliable spring operating mechanism (manual or electric, electric with manual function or close-range remote control operation), the energy storage motor has low power, low energy consumption for opening and closing, and the operating mechanism is sealed in the box, which effectively prevents the rust of parts and ensures the reliability of the mechanism;
◆The pillar is made of imported epoxy resin and outsourced silicone rubber material, which has the characteristics of high and low temperature resistance, UV resistance, and aging resistance;
◆ External two-phase or three-phase protection current transformer, with inrush current controller, to achieve overcurrent protection and fault current quick-break protection, and the protection delay time is adjustable:
◆The integrated structure of configurable phase-to-phase protection CT and zero-sequence CT, with intelligent controller (external power supply PT provides operating power), which can realize parameter setting, single-phase grounding protection (watchdog), three-stage protection, reclosing, fault accident memory and other functions; the controller is equipped with corresponding communication modules, data upload to the main station, fault feedback and "four remote" functions, forming an intelligent circuit breaker to realize the distribution network automation function;
◆The circuit breaker can be equipped with an isolation knife switch (single or double side), three-phase linkage, so that the incoming (outgoing) line side forms an obvious isolation break, and there is a reliable mechanical anti-misoperation interlock between the main switch and the isolation switch to ensure safe and reliable operation.
Appearance and installation dimensions
Ⅰ. Appearance of ZW32-12 factory circuit breaker (miniaturized with CT)

Ⅱ.ZW32-12T circuit breaker appearance (conventional with CT)

Ⅲ. ZW32-12G/T circuit breaker appearance (miniaturized with CT)

Ⅳ.Appearance of ZW32-12GT circuit breaker (conventional with CT)

Ⅴ. Appearance of ZW32F-12T circuit breaker (intelligent type)

Ⅵ. Appearance of ZW32F-12GT circuit breaker (intelligent type)

Ⅶ.ZW32F-12T circuit breaker installation diagram (box-type intelligent type)

Ⅷ. Installation diagram of ZW32F-12T circuit breaker [hood-type intelligent type]

Contact Us
If you need further assistance or have specific questions about the vacuum circuit breaker model (ZW32-12), feel free to ask!
For technical support, quotations, or detailed specifications, you may provide:
Required parameters (e.g., rated current, breaking capacity).
Application scenario (e.g., power distribution, industrial use).
We'll help you refine the details or connect you with relevant resources. Let us know how we can assist!
Email:pannie@hdswitchgear.com.
Our factory



Our Certificate





Hot Tags: zw32-12(g)t outdoor high voltage ac vacuum circuit breaker, GW8 Outdoor Neutral Disconnecting Switch, HXGN 12 Unit Gear Main, GZDW Power Supply Control Unit, ZW51-12 Outdoor Vacuum Circuit Breaker, Box Enclosed Euro Distribution, XGN7 12 Boxed Fixed Gear