LW3-12 Outdoor Sulfur Hexafluoride Circuit Breaker
Production Introduction
Overview:
LW3-12 Outdoor Sulfur Hexafluoride Circuit Breaker is an outdoor high-voltage switchgear with a three-phase AC rated voltage of 12kV and a frequency of 50Hz. It is mainly used to open and close the load current, overload current and short circuit current of the power system.
LW3-12 outdoor SF6 circuit breaker is a new generation of products independently developed by our Shaanxi Huadian Electric Co., Ltd. in response to the new requirements of the State Grid primary and secondary fusion of switches on the column, the switch configuration fully meets the requirements, which is convenient for unified procurement and mass production of the State Grid.
Structure:
The circuit breaker box material is made of 3mm304 stainless steel, and the protection level is not less than IP67; The housing has a clear point and closing position indicator located on the ground that is easy to observe, and the indicator is reliably connected to the operating mechanism to indicate reliable action.
The screws use anti-rust grounding screws with a diameter of 12 mm, and the grounding points are marked with a grounding symbol.
The surface of the shell is raised and does not store water for a long time.
The housing has a handle handle to avoid pulling out the line sleeve.
The lifting ring is configured to keep the switchgear in the suspension level and there is no frictional contact between the chain and any component, avoiding scratching the surface of the box during the lifting process.
The nameplate is made of 304 stainless steel, which can withstand wind and rain, corrosion resistance, ensure that the use of the process is clearly visible, and the nameplate content meets the requirements of relevant national standards.
Technical parameters of Current transformer and zero-sequence current transformer:
a. Current transformer ratio: phase current 600/1, zero sequence current 20/1. Accuracy Level: Primary Phase Current: Measurement accuracy class 0.5, protection 5P10.
b. The error is less than or equal to 3% when the zero-sequence primary input current is 1A to the rated current, and when the primary current is 100A, the error is less than or equal to 10%.
c. Zero-sequence voltage accuracy class is 3P.
d. Capacity requirements: phase: ≥1VA (600A/1A), ≥2.5VA (600A/5A)
e. Zero sequence: ≥ 0.5VA to meet the supporting requirements (according to the length of the cable 12 meters, with the FTU and line loss module, to meet the line loss metering and fault determination requirements).
Advantage:
The LW3-12 Outdoor Sulfur Hexafluoride Circuit Breaker has compact structure, reasonable layout and complete functions.
There is protect Current transformer, zero-sequence Current transformer and zero-sequence voltage sensors used in the cricuit breaker, with a wide measurement range, high measurement accuracy, high reliability, complete analog quantity is convenient to accurately determine various faults of the line.
Specification
The main technical parameters of circuit breakers:
| No. | Item | Unit | Data | ||
| 1 | Rated Voltage | kV | 10 | ||
| 2 | Maximum operating voltage | kV | 11.5 | ||
| 3 | Rated Insulation(1min power frequency withstand voltage) | kV | 42 | ||
| 4 | Rated Insulation(Rated lightning impulse withstand voltage) | kV | 75 | ||
| 5 | Rated Frequency | Hz | 50 | ||
| 6 | Rated Current | A | 400 / 630 | ||
| 7 | Rated short-circuit breaking current | kA | 6.3 / 8 /12.5 | ||
| 8 | Heterogeneous ground reopening current | kA | 5.5 / 7.1 / 10.9 | ||
| 9 | Zero gauge voltage breaking current | A | 400 / 630 | ||
| 10 | Rated order of operations | / | O-0.3s-CO-180s-CO | ||
| 11 | Rated closing current(Peak) | kA | 16 / 20 / 31.5 | ||
| 12 | Rated dynamic stabilized current (Peak) | kA | 16 / 20 / 31.5 | ||
| 13 | Thermally stabilized current | kA | 6.3 / 8 / 12.5 | ||
| 14 | Thermally stabilized time | s | 4 | ||
| 15 | Average closing speed | m/s | 2.4 ~ 2.8 | ||
| 16 | Average opening speed | m/s | 2.4 ~ 2.8 | ||
| 17 | Closing time | s | ≤ 0.06 | ||
| 18 | Opening time | s | ≤ 0.04 | ||
| 19 | Rated operation pressure (≤20℃) | Mpa | 0.35 | ||
| 20 | Minimum operation pressure (≤20℃) | Mpa | 0.25 | ||
| 21 | Annual gas leakage rate | % | ≤ 1 | ||
| 22 | Service Lifetime | t | 10000 | ||
| 23 | Sf6 moisture content | Ppm | ≤ 150 | ||
Prodection details
Product outline and installation dimensions:
(Unit:mm)

Company Profile
Shaanxi Huadian Electric Co., Ltd. is located in Baoji High-tech Development Zone, Shaanxi Province, China. It is a modern high-tech enterprise specializing in the production of vacuum circuit breakers integrating R&D, manufacturing and sales.
Shaanxi Huadian Electric Co., Ltd. provides customers with first-class products and services, creating value for customers and the country.
Shaanxi Huadian products have been widely used in power plants, metallurgy, petrochemicals, railways, mines, radio and television, urban construction and rural power grid reconstruction projects, and are well received by users for their high-quality products and services.

Product Workshop






Prodect qualification



Certifications



Hot Tags: lw3-12 outdoor sulfur hexafluoride circuit breaker, thermal power circuit breaker, generator circuit breaker, refurbished circuit breaker, manual operation circuit breaker, hospital circuit breaker, signal circuit breaker